Products
Home | F.R.P. Cooling Tower | NWQ Crosswind Cooling Tower | NWQ Crosswind cooling tower | NWQ Low Noise Crosswind Cross Flow Cooling Tower
NWQ Low Noise Crosswind Cross Flow Cooling Tower
Product Origin Guangdong
Brand NEWIN
Shipping Port Shenzhen
Color Yellow /Grey/Blue/White
Lead Time 2-6 weeks
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

Height of tower body under 3 meters, it is very suitable for installation in general building and high-rise building at technical equipment layer or middle layer, which is solved the problem of the inconvenient installation for standard cooling towers installed at the building middle layer, also makes the installation of the cooling tower easily in different area. Side inlet/outlet wind structure has installed on the position of the warm air of the cooling tower, which makes back flow of warm air greatly reduced, and improves the cooling efficiency of the cooling tower. Because installed on the middle layer, it reduces the working head of the air conditioning circulating water system, which reduces the air conditioning system of the construction costs, greatly reduce the operation cost of the system.

 


 1) Technical data of  NWQ Series Crosswind Low Noise FRP water cooling tower 


Model

Water 

Flow

 (m3/h)

Fan diameter (mm)

Weight (kg) Overall Dimension  (mm)

Water 

Pressure  

 (Kpa)

Net 

weight

Run. 

Weight

L W H
 NWQ-8 8 600 90 260 1360 820 1500 20
NWQ-10 10 600 100 270 1360 820 1500 20
NWQ-15 15 730 110 280 1360 1120 1500 20
NWQ-20 20 730 170 340 1360 1120 1500 20
NWQ-25 25 730 192 490 1870 1320 1500 26
NWQ-30 30 890 200 500 1870 1320 1960 26
NWQ-40 4 930 450 1000 1870 1320 1960 30
NWQ-80 200 1500 860 2260 2000 3200 3170 40
NWQ-100 225 1500 1060 2460 2500 3200 3170 40
NWQ-125 250 1800 1280 3030 3000 3200 3170 42
NWQ-150 300 2100 1380 3750 3250 3500 3170 42
NWQ-175 350 2100 1500 4010 3750 3500 3170 47
NWQ-200 400 2400 1800 4220  3750 3500 3770 47
NWQ-225 450 2400 1910 4350 4000 3500 3770 53
NWQ-250 500 2400 2580 5480 4500 3500 3770 53


 2) Foundation of NWQ series crosswind square type FRP water cooling tower 


Model

L  (mm)

L1   (mm)

W (mm)

W1   (mm)

W2 (mm)

NWQ-8

830

 

650

 

 

NWQ-10

830

 

650

 

 

NWQ-15

830

 

850

 

 

NWQ-20

830

 

850

 

 

NWQ-25

1340

 

1050

 

 

NWQ-30

1340

 

1050

 

 

NWQ-40

1340

 

1050

 

 

NWQ-80

2260

1960

2750

950

1500

NWQ-100

2760

2460

2750

950

1500

NWQ-125

3260

2960

2750

950

1500

NWQ-150

3510

3210

2950

1150

1500

NWQ-175

4010

3710

2950

1150

1500

NWQ-200

4010

3710

 2950

1150

1500

NWQ-225

4260

3960

2950

1150

1500

NWQ-250

4760

4460

2950

1150

1500

 

 

 3) Pipeline of NWQ Crosswind Cross Flow F.R.P Cooling Tower

 

Model

Inlet  (mm)

Outlet

(mm)

Overflow

 (mm)

Drain

 (mm)

Quick feeding 

(mm)

 Auto. 

feeding 

(mm)

NWQ-8

40

40

25

25

15

 

NWQ-10

40

40

25

25

15

 

NWQ-15

50

50

25

25

15

 

NWQ-20

50

50

25

25

15

 

NWQ-25

80

80

25

25

15

 

NWQ-30

80

80

25

25

15

 

NWQ-40

80

80

25

25

15

 

NWQ-80

125

125

80

80

25

40

NWQ-100

125

125

80

80

25

40

NWQ-125

150

150

80

80

25

40

NWQ-150

150

150

80

80

25

40

NWQ-175

125 x 2

200

80

80

25

40

NWQ-200

150 x 2

200

80

80

25

40

NWQ-225

150 x 2

200

80

80

25

40

NWQ-250

150 x 2

250

80

80

25

40

 

under construction
under construction
under construction
Recently Viewed Products
  • 225 RT bottle type cooling tower Counter Flow Round Type Cooling Tower NRT-225

    NRT series cooling towers' performance was strictly examined by "Quality Supervision and Inspection Center of National Glass work" in 2006, the result showed NRT series cooling towers completely comply with all national standards.   Design Features NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.   Casing and Water Basin Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.   Fan Blades Aluminum alloy axial flow fan with adjustable pitch blades are applied and being balanced so that it can operation stably and quietly. Blades of fan can be adjusted according to the requirement of air volume.To assure that the maximum effective of exhausting air.     Fan Drive Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.   Water Distribution   The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance.       Infill    Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degreeC water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.    

  • counter flow cooling tower NWI Industrial FRP Cooling Tower

    NWI Seires Industrial Cooling Tower is widely used in industries of Electric Power, Petroleum, Chemical Engineering, Chemical Fertilizer, Smelt, etc. Cooling water capacity ranges from 800 m3/h - 4000 m3/h. According to Customers' request, we also supply high temperature type, sewage type, and also designed to different shape to match with the customer's site location.

  • RTS Counter Flow Turbine Drive Cooling Tower RTS Counter Flow Turbine Drive Cooling Tower

    Components Instruction Turbine The reaction turbine drives fan directly, no other reducer equipment. Fan air volume is changed by water flow, realizes fan, water, power integrated control Infill  Brand new PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance.  We have different materials to suit different water temperature. What's more, the PVC filler's compact package design is convenient to take out for cleaning, and the special designed configuration of the filling incorporates the function of drift eliminator, louver and wet deck surface. Steel Structure  Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed. Distribution System Hot water distribution system is used F.R.P parts, non-corrosive and long life, and are specially designed for uniform distributing and ease of inspection. A distribution cover is attached on top to prevent    water from splashing out and other dirt to come into the water.      Inspection Door Inspection doors are used to provide a convenient access to the interior for inspection, maintenance, adjustment of the internal parts, like float valve, cleaning up the lift-out strainer and flushing of the water basin.             Technical Data of RTS Series Cross Flow Turbine Cooling Tower Model Water  Flow  (m3/h)  Fan Weight (kg) Overall Dimension  (mm) Water  Pressure    (Kpa) Net  weight Run.  Weight L W H  RTS-100-1 100 1500 765 1970 1800 3160 3700 160 RTS-125-1 125 1800 910 2570 2000 3360 3700 160 RTS-150-1 150 1800 970 2800 2400 3360 3700 165 RTS-175-1 175 2100 1150 3230  2600 3960 3700 165 RTS-200-1 200 2100 1280 3580 2900 3960 3700 180 RTS-225-1 225 2400 1460 4050 2900 4260 3700 180 RTS-250-1 250 2400 1510 4310 3200 4260 3700 180 RTS-300-2 300 1800 1910 5600 4800 3360 3700 170 RTS-350-2 350 2100 2270 6430 5200 3960 3700 170 RTS-400-2 400 2100 2530 7010 5800 3960 3700 185 RTS-450-2 450 2400 2880 7960 5800 4260 3700 185  RTS-500-2 500  2400 2990  8580  6400   4260  3700  185   RTS-525-3  525 2100  3390  9630  7800   3960  3700  190   RTS-600-3  600 2100   3780 10680  8700   3960  3700  190   RTS-700-4  700 2100  4510  12830  10400   3960   3700 190   RTS-800-4  800 2100  5030  13990   11600  3960  3700  190   RTS-900-4  900 2400 5730   15890  11600  4260 3700  190   RTS-1000-5  1000 2100 6250  17630  14500   3960 3700  190    Remark:   1. Working condition: dry bulb temp.=31.5℃, wet bulb temp.=28℃, inlet water=37℃, outlet water=32℃, atmospheric pressure=99.4Kpa.   2. When installing pipeline of the cooling towers, Y-strainers, valves and pressure gauges are needed at the water inlet pipe.   3. Keep foundation surface level, error limit ±5mm.   4. Special design for other model are acceptable by technical department.  

  • 600m³/h cross flow cooling tower cross flow cooling tower NST-600

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • cross flow closed circuit cooling tower LKM-125 cross flow closed circuit cooling tower LKM-125

    LKM series closed circuit cooling tower is a kind of high efficient heat exchange equipment which comes into being on the basis of absorbing the most advanced foreign heat-exchange technology.  The Air intake style is inlet from the bottom of the tower, which is alternating direction interactive with the fall down spray water and from to saturated vapor in the process. The heat is exhausted out of tower by the fan and the water is collected to bottom tank and circulate continuously by the special evaporator. There is no heat sinking fillings inside of the tower, so more space is saved to increase coil area. This apply especially to suit for smaller fluid cooling fluid in low temperature or small temperature difference.     Technical parameters of LKM series closed circuit cooling tower          Item  Water Flow (m3/h) Fan Spray Pump Inlet/Outlet  Pipe Dia.  (mm) Weight (kg) Dimension          Model Air Volume   (m3/h) Power  (KW) Flow  (m³/h) Power  (KW) Net Weight Run. Weight L×W×H      (mm) LKM-5 5 10500 0.55 14 0.75 50 T:350 600 1150x900x1920 LKM-8 8 13050 0.75 14 0.75 65 T:400 700 1150x1150x1920 LKM-10 10 26100 0.75*2 30 1.1 65 T:520 1000 2000x1150x2200 LKM-15 15 26100 0.75*2 30 1.1 65 T:570 1100 2000x1150x2200 LKM-20 20 36600 1.1*2 40 1.5 80 T:650 1600 2500x1150x2200 LKM-25 25 36600 1.1*2 40 1.5 80 T:750 1700 2500x1150x2350 LKM-35 35 40600 1.5*2 40 1.5 80 T:850 1800 2500x1400x2650 LKM-40 40 40600 1.5*2 60 1.5 100 T:1050 2000 2500x1400x2650 40600 1.5*2 60 1.5 100 G:2150 3000 3000x1400x2650 LKM-50 50 46900 2.2*2 60 1.5 100 T:1250 2300 2500x1400x2650 46900 2.2*2 60 1.5 100 G:2450 3500 3000x1400x2650 LKM-60 60 53000 2.6*2 60 1.5 100 T:1350 2400 2500x1400x2650 53000 2.6*2 60 1.5 100 G:2650 3700 3000x1400x2650 LKM-70 70 63800 3.5*2 65 2.2 100 T:1650 3000 3000x1400x2850 63800 3.5*2 65 2.2 100 G:2950 4300 3518x1400x3310 LKM-80 80 90000 4*2 65 2.2 125 T:1850 3300 3000x1400x2850 90000 4*2 65 2.2 125 G:3560 5000 3518x2180x3310 LKM-100 100 90000 4*2 110 3 125 T:2050 3800 3000x2180x2850 90000 4*2 110 3 125 G:4150 5900 3518x2180x3310 LKM-125 125 110000 5.5*2 110 3 100*2 T:2450 4300 3518x2180x3250 110000 5.5*2 110 4 100*2 G:5150 7000 4010x2180x3910 LKM-150 150 150000 7.5*2 110 3 100*2 T:3150 4300 3518x2180x2850 150000 7.5*2 140 4 100*2 G:6500 8100 4010x2980x3910 LKM-175 175 180000 7.5*2 170 5.5 100*2 T:3700 7100 4010x2980x3910 180000 7.5*2 220 7.5 100*2 G:7120 10500 5380x2980x3910 LKM-200 200 220000 7.5*2 170 5.5 125*2 T:4180 7600 4010x2980x3910 220000 7.5*2 220 7.5 125*2 G:8300 11700 5380x2980x3910 LKM-250 250 300000 11*2 170 5.5 125*2 T:5050 8900 4510x2980x3910 300000 11*2 220 7.5 125*2 G:10680 14600 5380x2180x3910 LKM-300 300 300000 7.5*4 220 3*2 100*4 T:6300 8600 7036x2180x2850 300000 7.5*4 220 3*2 100*4 G:12100 16200 8020x2980x3910 LKM-350 350 360000 7.5*4 340 5.5*2 125*4 T:7400 14200 8020x2980x3910 360000 7.5*4 440 7.5*2 125*4 G:14240 21000 107600x2980x3910 LKM-400 400 440000 7.5*4 340 5.5*2 125*4 T:8360 15200 8020x2980x3910 440000 7.5*4 440 7.5*2 125*4 G:16600 23400 107600x2980x3910 LKM-500 500 600000 11*4 340 5.5*2 125*4 T:10100 17800 8020x2980x3910 600000 11*4 440 7.5*2 125*4 G:21360 29200 107600x2980x3910  ※ We reserve the right to modify the above information without further notice.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.