Products
Home | F.R.P. Cooling Tower | NWQ Crosswind Cooling Tower | NWQ Crosswind cooling tower | NWQ Low Noise Crosswind Cross Flow Cooling Tower
NWQ Low Noise Crosswind Cross Flow Cooling Tower
Product Origin Guangdong
Brand NEWIN
Shipping Port Shenzhen
Color Yellow /Grey/Blue/White
Lead Time 2-6 weeks
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

Height of tower body under 3 meters, it is very suitable for installation in general building and high-rise building at technical equipment layer or middle layer, which is solved the problem of the inconvenient installation for standard cooling towers installed at the building middle layer, also makes the installation of the cooling tower easily in different area. Side inlet/outlet wind structure has installed on the position of the warm air of the cooling tower, which makes back flow of warm air greatly reduced, and improves the cooling efficiency of the cooling tower. Because installed on the middle layer, it reduces the working head of the air conditioning circulating water system, which reduces the air conditioning system of the construction costs, greatly reduce the operation cost of the system.

 


 1) Technical data of  NWQ Series Crosswind Low Noise FRP water cooling tower 


Model

Water 

Flow

 (m3/h)

Fan diameter (mm)

Weight (kg) Overall Dimension  (mm)

Water 

Pressure  

 (Kpa)

Net 

weight

Run. 

Weight

L W H
 NWQ-8 8 600 90 260 1360 820 1500 20
NWQ-10 10 600 100 270 1360 820 1500 20
NWQ-15 15 730 110 280 1360 1120 1500 20
NWQ-20 20 730 170 340 1360 1120 1500 20
NWQ-25 25 730 192 490 1870 1320 1500 26
NWQ-30 30 890 200 500 1870 1320 1960 26
NWQ-40 4 930 450 1000 1870 1320 1960 30
NWQ-80 200 1500 860 2260 2000 3200 3170 40
NWQ-100 225 1500 1060 2460 2500 3200 3170 40
NWQ-125 250 1800 1280 3030 3000 3200 3170 42
NWQ-150 300 2100 1380 3750 3250 3500 3170 42
NWQ-175 350 2100 1500 4010 3750 3500 3170 47
NWQ-200 400 2400 1800 4220  3750 3500 3770 47
NWQ-225 450 2400 1910 4350 4000 3500 3770 53
NWQ-250 500 2400 2580 5480 4500 3500 3770 53


 2) Foundation of NWQ series crosswind square type FRP water cooling tower 


Model

L  (mm)

L1   (mm)

W (mm)

W1   (mm)

W2 (mm)

NWQ-8

830

 

650

 

 

NWQ-10

830

 

650

 

 

NWQ-15

830

 

850

 

 

NWQ-20

830

 

850

 

 

NWQ-25

1340

 

1050

 

 

NWQ-30

1340

 

1050

 

 

NWQ-40

1340

 

1050

 

 

NWQ-80

2260

1960

2750

950

1500

NWQ-100

2760

2460

2750

950

1500

NWQ-125

3260

2960

2750

950

1500

NWQ-150

3510

3210

2950

1150

1500

NWQ-175

4010

3710

2950

1150

1500

NWQ-200

4010

3710

 2950

1150

1500

NWQ-225

4260

3960

2950

1150

1500

NWQ-250

4760

4460

2950

1150

1500

 

 

 3) Pipeline of NWQ Crosswind Cross Flow F.R.P Cooling Tower

 

Model

Inlet  (mm)

Outlet

(mm)

Overflow

 (mm)

Drain

 (mm)

Quick feeding 

(mm)

 Auto. 

feeding 

(mm)

NWQ-8

40

40

25

25

15

 

NWQ-10

40

40

25

25

15

 

NWQ-15

50

50

25

25

15

 

NWQ-20

50

50

25

25

15

 

NWQ-25

80

80

25

25

15

 

NWQ-30

80

80

25

25

15

 

NWQ-40

80

80

25

25

15

 

NWQ-80

125

125

80

80

25

40

NWQ-100

125

125

80

80

25

40

NWQ-125

150

150

80

80

25

40

NWQ-150

150

150

80

80

25

40

NWQ-175

125 x 2

200

80

80

25

40

NWQ-200

150 x 2

200

80

80

25

40

NWQ-225

150 x 2

200

80

80

25

40

NWQ-250

150 x 2

250

80

80

25

40

 

under construction
under construction
under construction
Recently Viewed Products
  • counter flow closed circuit cooling tower LKM-10 Counter flow closed circuit cooling tower LKM-10

    LKM series closed circuit cooling tower is a kind of high efficient heat exchange equipment which comes into being  on the basis of absorbing the most advanced foreign heat-exchange technology. The Air intake style is inlet from the bottom of the tower,  which is alternating direction interactive with the fall down  spray water and from to saturated vapor in the process.  The heat is exhausted out of tower by the fan and the water  is collected to bottom tank and circulate continuously by the  special evaporator. There is no heat sinking fillings inside of  the tower, so more space is saved to increase coil area. This  apply especially to suit for smaller fluid cooling fluid in low  temperature or small temperature difference.   Technical parameters of LKM series closed circuit cooling tower          Item  Water Flow (m3/h) Fan Spray Pump Inlet/Outlet  Pipe Dia.  (mm) Weight (kg) Dimension          Model Air Volume   (m3/h) Power  (KW) Flow  (m³/h) Power  (KW) Net Weight Run. Weight L×W×H      (mm) LKM-5 5 10500 0.55 14 0.75 50 T:350 600 1150x900x1920 LKM-8 8 13050 0.75 14 0.75 65 T:400 700 1150x1150x1920 LKM-10 10 26100 0.75*2 30 1.1 65 T:520 1000 2000x1150x2200 LKM-15 15 26100 0.75*2 30 1.1 65 T:570 1100 2000x1150x2200 LKM-20 20 36600 1.1*2 40 1.5 80 T:650 1600 2500x1150x2200 LKM-25 25 36600 1.1*2 40 1.5 80 T:750 1700 2500x1150x2350 LKM-35 35 40600 1.5*2 40 1.5 80 T:850 1800 2500x1400x2650 LKM-40 40 40600 1.5*2 60 1.5 100 T:1050 2000 2500x1400x2650 40600 1.5*2 60 1.5 100 G:2150 3000 3000x1400x2650 LKM-50 50 46900 2.2*2 60 1.5 100 T:1250 2300 2500x1400x2650 46900 2.2*2 60 1.5 100 G:2450 3500 3000x1400x2650 LKM-60 60 53000 2.6*2 60 1.5 100 T:1350 2400 2500x1400x2650 53000 2.6*2 60 1.5 100 G:2650 3700 3000x1400x2650 LKM-70 70 63800 3.5*2 65 2.2 100 T:1650 3000 3000x1400x2850 63800 3.5*2 65 2.2 100 G:2950 4300 3518x1400x3310 LKM-80 80 90000 4*2 65 2.2 125 T:1850 3300 3000x1400x2850 90000 4*2 65 2.2 125 G:3560 5000 3518x2180x3310 LKM-100 100 90000 4*2 110 3 125 T:2050 3800 3000x2180x2850 90000 4*2 110 3 125 G:4150 5900 3518x2180x3310 LKM-125 125 110000 5.5*2 110 3 100*2 T:2450 4300 3518x2180x3250 110000 5.5*2 110 4 100*2 G:5150 7000 4010x2180x3910 LKM-150 150 150000 7.5*2 110 3 100*2 T:3150 4300 3518x2180x2850 150000 7.5*2 140 4 100*2 G:6500 8100 4010x2980x3910 LKM-175 175 180000 7.5*2 170 5.5 100*2 T:3700 7100 4010x2980x3910 180000 7.5*2 220 7.5 100*2 G:7120 10500 5380x2980x3910 LKM-200 200 220000 7.5*2 170 5.5 125*2 T:4180 7600 4010x2980x3910 220000 7.5*2 220 7.5 125*2 G:8300 11700 5380x2980x3910 LKM-250 250 300000 11*2 170 5.5 125*2 T:5050 8900 4510x2980x3910 300000 11*2 220 7.5 125*2 G:10680 14600 5380x2180x3910 LKM-300 300 300000 7.5*4 220 3*2 100*4 T:6300 8600 7036x2180x2850 300000 7.5*4 220 3*2 100*4 G:12100 16200 8020x2980x3910 LKM-350 350 360000 7.5*4 340 5.5*2 125*4 T:7400 14200 8020x2980x3910 360000 7.5*4 440 7.5*2 125*4 G:14240 21000 107600x2980x3910 LKM-400 400 440000 7.5*4 340 5.5*2 125*4 T:8360 15200 8020x2980x3910 440000 7.5*4 440 7.5*2 125*4 G:16600 23400 107600x2980x3910 LKM-500 500 600000 11*4 340 5.5*2 125*4 T:10100 17800 8020x2980x3910 600000 11*4 440 7.5*2 125*4 G:21360 29200 107600x2980x3910  ※ We reserve the right to modify the above information without further notice.

  • Counter Flow Square Cooling Tower NSH-700 Counter Flow Square Cooling Tower NSH-700

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • cross/mixed flow closed circuit cooling tower LKH-70 cross/mixed flow closed circuit cooling tower LKH-70

    1.Water processing capacity: 70m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • FRP Open Round Water Cooling Tower NRT-50 FRP Open Round Water Cooling Tower NRT-50

    NRT series cooling towers' performance was strictly examined by "Quality Supervision and Inspection Center of National Glass work" in 2006, the result showed NRT series cooling towers completely comply with all national standards.   Design Features NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.   Casing and Water Basin Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.   Fan Blades Aluminum alloy axial flow fan with adjustable pitch blades are applied and being balanced so that it can operation stably and quietly. Blades of fan can be adjusted according to the requirement of air volume.To assure that the maximum effective of exhausting air.     Fan Drive Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.   Water Distribution   The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance.       Infill    Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degreeC water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.    

  • 150m³/h cross flow cooling tower cross flow cooling tower NST-150

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.