Products
Home | F.R.P. Cooling Tower | NRT Round Cooling Tower | NRT-10 | Mini Steam Boiler Cooling Tower NRT-10
Mini Steam Boiler Cooling Tower NRT-10
Product Origin Guangdong
Brand NEWIN
Shipping Port Shenzhen
Color Yellow/White/Gray/Blue
Lead Time 5 working days
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

The small round type cooling tower are mainly used in gas industry, air conditioning system. Here we mainly introduce the technical data, structure and foundation of the round type cooling tower NRT-10. For different working condition, please contact us for correct solution. 

  

1)  Technical data of circular type cooling tower NRT-10

Item

Content

Parameter

Basic data

 

 Type

Counter-flow round type

 Model

NRT-10

 Water flow

7.81 m3/h

 Inlet/outlet temperature

37°C32°C

 Dry/Wet bulb temperature

31.5°C 27°C

 Cooling capacity

39,050 kcal/h

 Power supply

380V3Ph50Hz

 Water quality

PH=6-8

Design data

 Air/water ratio

0.62 kg/kg

 Drift loss

≤0.02%

 Evaporating loss

≤0.833%

 Net weight

46 kg

 Running weight

190kg

Fan data

 Fan type

Axial-flow 

 Air flow

4,30m3/h

 Fan rotate speed

910r/min

 Diameter (F)

600 mm

 Blade quantity

3 pcsset

 Type of drive

direct

 Motor rotate speed

910r/min

 Motor power

0.18 kW

 Motor starting method

direct

Dimension

 Tower diameter (F)

945 mm

 Tower height (H)

1,530 mm

 Inlet/outlet pipe dimension (DN)

40mm40mm

 Full/drain pipe dimension (DN)

25mm25mm

 Quick feed pipe dimension (DN)

15mm


2) Structural of bottle type cooling tower NRT-10

 

3) Foundation of round type cooling tower NRT-10

 

※ We reserve the right to modify the above information without further notice.

The main parts of cooling tower consists of motor, fan, infill, sprinkler system, F.R.P parts, etc. We use great quality of the cooling tower parts to make sure the great performance and long lifespan of the Newin cooling towers. If customers have other special requirements for the cooling tower, we will try our best to satisfy their needs.

 

       
       

 

Parts  Material  Remark

Water Basin

 F.R.P Water-resistance resin and high quality fiberglass mat

 Casing

 F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type, other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard

 Fan

 A.B.S Aluminum alloy material for optional 

 Infill

 P.V.C  film For high temperature inlet water, UPVC and PP material for optional

 Air inlet screen  

 P.V.C   F.R.P  for optional

 Sprinkler head

 A.B.S  Aluminum alloy material for optional

 Sprinkler pipe

 P.V.C  For high temperature inlet water, hot-dip galvanized steel for optional

 Bolts & Nuts 

 Electroplated   Stainless steel 304, 316 for optional






















Cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc.  Those industries  could be divided into 4 categories as follows:
♦  Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦  Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦  other industries...

 

Below is some round type cooling towers' project in different industries.

   
   
   
   

Drawing and parameters:


Technical specification of cooling tower NRT-10

Outline dimension drawing of cooling tower NRT-10

Foundation size and construction drawing of cooling tower NRT-10


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • 525m³/h cross flow cooling tower cross flow cooling tower NST-525

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • cross/mixed flow closed circuit cooling tower LKH-100 cross/mixed flow closed circuit cooling tower LKH-100

    1.Water processing capacity: 100m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • 150m³/h cross flow cooling tower cross flow cooling tower NST-150

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • Counter Flow Square Cooling Tower NSH-80 Counter Flow Square Cooling Tower NSH-80

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • Square Type Cooling Tower NSH-300 Square Type Cooling Tower NSH-300

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.