Products
Home | Closed Circuit Cooling Tower | LKH Mixed(cross) Flow | LKH-60 | cross/mixed flow closed circuit cooling tower LKH-60
cross/mixed flow closed circuit cooling tower LKH-60
Product Origin China
Brand NEWIN
Item NO. LKH-60
Shipping Port Shenzhen
Color steel white
Lead Time 15 working day
Payment T/T,L/C
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

Cross flow closed circuit cooling tower

LKH-60 specification

 

I. Design Condition

   Water processing capacity: 60 m3/ h

   △t = 5℃( Inlet 37, outlet 32℃ )

          Design wet bulb temperature28℃ 

          Design dry bulb temperature: 31.5℃ 

          Atmosphere: 99,400Pa

D

II. Selection Model

   Closed circuit cross flow cooling tower 

   Model: LKH-60

 

III. Cooling tower performance data sheet(single cell) 

          

Model

LKH-60

Water flow rate

60m3/ h

Temperature in

37

Temperature out

32(2-5 above WBT in summer)

WTB

28

Temperature decrease

5

Heat exchanging capacity

300,000 kcal/h

Power

3φ-400V/50Hz

Total power

5.5kW

Drift loss

0.005%

Noise level

Not more than 75dB(A) According to GB9068 measurement

Axial fan

Quantity

3 sets

Air volume

48000m3/ h

Power

1.1Kwx3

Speed

720r/min

Air pressure

140pa

Spray pump

Quantity

1set

Water volume

45 m3/ h

Power

2.2Kw

Coil pressure

1.2Mpa

Water Resistance

<80KPa

Inlet pipe diameter

DN80

Outlet pipe diameter

DN80

dimension

Length

3100 mm

Width

1970 mm

Height

2395 mm

Weight

Net weight(kg)

1250

Operation weight(kg)

3950


Components list

No.

Name

Qty

Specification

 

Origin

Performance

1

Coil cooler

(coil type)

set

 

2

copper tube

Φ16mm、 

δ=0.65mm

shanghai

 

 

2

Casing

set

1

δ= 2mm

Shanghai

high strength galvanized steelThe material is composed of aluminum, zinc, such as silicon, has a good anti-corrosive and insulating performance, service life is 3 to 6 times that of the normal galvanized sheet.

3

Water basin

set

1

δ= 2mm

Shanghai

4

Eliminator

set

1

PVC

Dongguan

Spray water loss 0.5%

5

Infill

set

1

PVC

Dongguan

Pure PVC

6

Fan blades

set

4

Aluminum alloy

Dongguan

high-strength aluminum alloy

7

Fan motor

set

4

Cast iron

Dongguan

ABB brand

IP55, TEFC

8

Bearing

set

4

NTN

Japan

Oil free, Japan imported

9

Air duct

Pic

4

Galvanized steel

Dongguan

Height 500mmprotection cover

10

Spray pump

set

1

In-line pump

Dongguan

Big flowsmall headwater-profcooling tower specialize

11

Spray pump motor

set

 

1

Total closed

Dongguan

 Executive Standard JIS-C4210

IP54Class F

12

Motor Bearing

set

1

NTN

Japan

Oil free

13

Spray pipe

set

1

Galvanized steel

 

 

14

Spray head

set

/

ABS type spiral nozzle

Shanghai

With pray balance tank

15

Water level control

pic

1

SUS float valve

Shanghai

Auto-feed water

16

Drain outlet

pic

1

SUS ball valve

Shanghai

 

17

Inlet&outlet

set

2

SUS Flange

Shanghai

 

18

air-inlet grille

Pic

6

PVC or aluminum zinc plate

Shanghai

 

19

Ladder

Pic

1

Galvanized steel

Shanghai

Application Industries:


  · High frequency power source capacitance

 

· Furnace

 

· Quenching water/oil tank


 

 · Hydraulic pressure station



· Pressing machine


 

 · Air compressor



· Central air-conditioning system


 

· Power generato

Drawing and parameters:


Technical specification of cooling tower LKH-60  1cell unit

Outline dimension drawing of cooling tower LKH-60  1cell unit


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • counter flow cooling tower Square Type Cooling Tower NSH-175

    NSH Series Counter flow Fiberglass Reinforced Plastic Square Type cooling towers uses counter flow air heat exchange technology, the cooling tower packing / cooling tower infill is made of high quality modified polyvinyl chloride (PVC) wave plate, to spread  the drench water area, and adopts fixed water sprinkling system, selection of ABS low pressure water spray nozzle, uniform water distribution, long service life, and with low water head, to save water distribution power system.

  • cross/mixed flow closed circuit cooling tower LKH-70 cross/mixed flow closed circuit cooling tower LKH-70

    1.Water processing capacity: 70m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • cross/mixed flow closed circuit cooling tower LKH-50 cross/mixed flow closed circuit cooling tower LKH-50

    1.Water processing capacity: 50m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • 900m³/h cross flow cooling tower cross flow cooling tower NST-900

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • 1000m³/h cross flow cooling tower cross flow cooling tower NST-1000

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.