Products
Home | Closed Circuit Cooling Tower | LKH Mixed(cross) Flow | LKH-100 | cross/mixed flow closed circuit cooling tower LKH-100
cross/mixed flow closed circuit cooling tower LKH-100
Product Origin China
Brand NEWIN
Item NO. LKH-100
Shipping Port Shenzhen
Color steel white
Lead Time 4-6 weeks
Payment T/T,L/C
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

Cross flow closed circuit cooling tower

LKH-100 specification

 

I.Requirements

   Water processing capacity100 m3/ h

   △t = 5℃( Inlet37, outlet 32℃ )

          Design wet bulb temperature28

II. Selection Model

  outlet temperature 32 selected model: 

   closed circuit cross flow cooling tower 

   Model: LKH-100

 

III. Cooling tower performance data sheet(single cell) 

          

Model

LKH-100

Water flow rate

100 m3/ h

Temperature in

37

Temperature out

32(2-5 above WBT in summer)

WTB

28

Temperature decrease

5

heat exchanging capacity

500,000 kcal/h

Power

3φ-380V/50Hz

Total power

5.5 kW

Drift loss

0.005%

Noise level

Not more than 75dB(A) According to GB9068 measurement

Axial fan

Quantity

3 sets

Air volume

48000m3/ h

Power

1.1Kw x 3

Speed

720r/min

Air pressure

140pa

Spray pump

Quantity

1set

Water volume

58 m3/ h

Power

2.2 Kw

Coil pressure

1.2Mpa

Water Resistance

80KPa

Inlet pipe diameter

DN100

Outlet pipe diameter

DN100

dimension

Length

3100 mm

Width

1970 mm

Height

2890 mm

Weight

Net weightkg

1630

Operation weightkg

4420

Components list

No.

Name

Qty

Specification

 

Origin

Performance

1

Coil cooler

(coil type)

set

 

2

copper tube

Φ16mm、 

δ=0.65mm

shanghai

 

 

2

Casing

set

1

δ= 2mm

Shanghai

high strength galvanized steelThe material is composed of aluminum, zinc, such as silicon, has a good anti-corrosive and insulating performance, service life is 3 to 6 times that of the normal galvanized sheet.

3

Water basin

set

1

δ= 2mm

Shanghai

4

Eliminator

set

1

PVC

Dongguan

Spray water loss 0.5%

5

Infill

set

1

PVC

Dongguan

Pure PVC

6

Fan blades

set

4

Aluminum alloy

Dongguan

high-strength aluminum alloy

7

Fan motor

set

4

Cast iron

Dongguan

ABB brand

IP55, TEFC

8

Bearing

set

4

NTN

Japan

Oil free, Japan imported

9

Air duct

Pic

4

Galvanized steel

Dongguan

Height 500mmprotection cover

10

Spray pump

set

1

In-line pump

Dongguan

Big flowsmall headwater-profcooling tower specialize

11

Spray pump motor

set

 

1

Total closed

Dongguan

 Executive Standard JIS-C4210

IP54Class F

12

Motor Bearing

set

1

NTN

Japan

Oil free

13

Spray pipe

set

1

Galvanized steel

 

 

14

Spray head

set

/

ABS type spiral nozzle

Shanghai

With pray balance tank

15

Water level control

pic

1

SUS float valve

Shanghai

Auto-feed water

16

Drain outlet

pic

1

SUS ball valve

Shanghai

 

17

Inlet&outlet

set

2

SUS Flange

Shanghai

 

18

air-inlet grille

Pic

6

PVC or aluminum zinc plate

Shanghai

 

19

Ladder

Pic

1

Galvanized steel

Shanghai

Application Industries:


  · High frequency power source capacitance

 

· Furnace

 

· Quenching water/oil tank


 

 · Hydraulic pressure station



· Pressing machine


 

 · Air compressor



· Central air-conditioning system


 

· Power generato

Drawing and parameters:


Technical specification of cooling tower LKH-100 1cell unit

Outline dimension drawing of cooling tower LKH-100  1cell unit


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • Fanless cooling tower NWE Fan-less FRP Cooling Tower

     NWE Fan-less cooling tower is born on basis of environmental protection and benefit to descendents, whole cooling tower is without fan and motor, which totally consists of static parts, completely comply with national standard GB7190.0-2008 on super low noise cooling tower. Meanwhile, NWE fan less cooling tower has no moving parts, which protects user's living environment to the largest extent.

  • counter flow closed circuit cooling tower LKM-150 Counter flow closed circuit cooling tower LKM-150

    LKM series closed circuit cooling tower is a kind of high efficient heat exchange equipment which comes into being on the basis of absorbing the most advanced foreign heat-exchange technology.  The Air intake style is inlet from the bottom of the tower, which is alternating direction interactive with the fall down spray water and from to saturated vapor in the process. The heat is exhausted out of tower by the fan and the water is collected to bottom tank and circulate continuously by the special evaporator. There is no heat sinking fillings inside of the tower, so more space is saved to increase coil area. This apply especially to suit for smaller fluid cooling fluid in low temperature or small temperature difference.   Technical parameters of LKM series closed circuit cooling tower          Item  Water Flow (m3/h) Fan Spray Pump Inlet/Outlet  Pipe Dia.  (mm) Weight (kg) Dimension          Model Air Volume   (m3/h) Power  (KW) Flow  (m³/h) Power  (KW) Net Weight Run. Weight L×W×H      (mm) LKM-5 5 10500 0.55 14 0.75 50 T:350 600 1150x900x1920 LKM-8 8 13050 0.75 14 0.75 65 T:400 700 1150x1150x1920 LKM-10 10 26100 0.75*2 30 1.1 65 T:520 1000 2000x1150x2200 LKM-15 15 26100 0.75*2 30 1.1 65 T:570 1100 2000x1150x2200 LKM-20 20 36600 1.1*2 40 1.5 80 T:650 1600 2500x1150x2200 LKM-25 25 36600 1.1*2 40 1.5 80 T:750 1700 2500x1150x2350 LKM-35 35 40600 1.5*2 40 1.5 80 T:850 1800 2500x1400x2650 LKM-40 40 40600 1.5*2 60 1.5 100 T:1050 2000 2500x1400x2650 40600 1.5*2 60 1.5 100 G:2150 3000 3000x1400x2650 LKM-50 50 46900 2.2*2 60 1.5 100 T:1250 2300 2500x1400x2650 46900 2.2*2 60 1.5 100 G:2450 3500 3000x1400x2650 LKM-60 60 53000 2.6*2 60 1.5 100 T:1350 2400 2500x1400x2650 53000 2.6*2 60 1.5 100 G:2650 3700 3000x1400x2650 LKM-70 70 63800 3.5*2 65 2.2 100 T:1650 3000 3000x1400x2850 63800 3.5*2 65 2.2 100 G:2950 4300 3518x1400x3310 LKM-80 80 90000 4*2 65 2.2 125 T:1850 3300 3000x1400x2850 90000 4*2 65 2.2 125 G:3560 5000 3518x2180x3310 LKM-100 100 90000 4*2 110 3 125 T:2050 3800 3000x2180x2850 90000 4*2 110 3 125 G:4150 5900 3518x2180x3310 LKM-125 125 110000 5.5*2 110 3 100*2 T:2450 4300 3518x2180x3250 110000 5.5*2 110 4 100*2 G:5150 7000 4010x2180x3910 LKM-150 150 150000 7.5*2 110 3 100*2 T:3150 4300 3518x2180x2850 150000 7.5*2 140 4 100*2 G:6500 8100 4010x2980x3910 LKM-175 175 180000 7.5*2 170 5.5 100*2 T:3700 7100 4010x2980x3910 180000 7.5*2 220 7.5 100*2 G:7120 10500 5380x2980x3910 LKM-200 200 220000 7.5*2 170 5.5 125*2 T:4180 7600 4010x2980x3910 220000 7.5*2 220 7.5 125*2 G:8300 11700 5380x2980x3910 LKM-250 250 300000 11*2 170 5.5 125*2 T:5050 8900 4510x2980x3910 300000 11*2 220 7.5 125*2 G:10680 14600 5380x2180x3910 LKM-300 300 300000 7.5*4 220 3*2 100*4 T:6300 8600 7036x2180x2850 300000 7.5*4 220 3*2 100*4 G:12100 16200 8020x2980x3910 LKM-350 350 360000 7.5*4 340 5.5*2 125*4 T:7400 14200 8020x2980x3910 360000 7.5*4 440 7.5*2 125*4 G:14240 21000 107600x2980x3910 LKM-400 400 440000 7.5*4 340 5.5*2 125*4 T:8360 15200 8020x2980x3910 440000 7.5*4 440 7.5*2 125*4 G:16600 23400 107600x2980x3910 LKM-500 500 600000 11*4 340 5.5*2 125*4 T:10100 17800 8020x2980x3910 600000 11*4 440 7.5*2 125*4 G:21360 29200 107600x2980x3910  ※ We reserve the right to modify the above information without further notice.

  • 700m³/h cross flow cooling tower cross flow cooling tower NST-700

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • Generator Used Cooling Tower NRT-40 Generator Used Cooling Tower NRT-40

    NRT series cooling towers' performance was strictly examined by "Quality Supervision and Inspection Center of National Glass work" in 2006, the result showed NRT series cooling towers completely comply with all national standards.   Design Features NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.   Casing and Water Basin Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.   Fan Blades Aluminum alloy axial flow fan with adjustable pitch blades are applied and being balanced so that it can operation stably and quietly. Blades of fan can be adjusted according to the requirement of air volume.To assure that the maximum effective of exhausting air.     Fan Drive Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.   Water Distribution   The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance.       Infill    Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degreeC water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.    

  • 300m³/h cross flow cooling tower Fiberglass Cross Flow Cooling Tower NST-300

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.