Products
Home | F.R.P. Cooling Tower | NST Cross Flow Cooling Tower | NST-600 | cross flow cooling tower NST-600
cross flow cooling tower NST-600
Product Origin Guangdong
Brand NEWIN
Shipping Port Shenzhen
Color Yellow/White/Gray/Blue
Lead Time 20 working days
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

Cross flow cooling tower, a type of cooling tower which water falling from the top tower vertically, air flow
through the water spray packing horizontally. Water and air flows orthogonally.  

  

1)  Technical data of cross flow square type cooling tower NST-600

Item

Content

Parameter

Note

Basic data

 

 Type

Cross flow square type

 

 Model

NST-600

2cells 

 Water flow

300 m3/h

 

 Inlet/outlet temperature

3732

ΔT=5

 Wet bulb temperature

31.5℃28

 

 Cooling capacity

2,135,000 kcal/h

 

 Noise value

63 dB(A)

Standard point

 Power supply

400V3P50Hz

 

 Water quality

PH=6-8

 

Design data

 Gas-water ratio

0.68kg/kg

 

 Water resistance

44.5kpa

 

 Drift loss

≤0.005%

 

 Evaporating loss

0.833%

 

 Net weight / Running weight

 5,160 kg/11,300 kg

 

Fan data

 Fan type

Axial-flow 

 

 Air flow

180,000 m3/h x 2

 

 Static pressure

74Pa

 

 Fan rotate speed

253 r/min

 

 DiameterF

2,850 mm

 Blade quantity

4 pcsset

 

 Motor power

5.5kW x 2

 2sets

 Type of drive

Direct drive

 

 Motor starting method

Star-Delta

 

Dimension

 L × W × H

6,500×5,550×4,100 mm

 

 Inlet pipe dimension (DN)

125mm

  4sets

 Outlet pipe dimension (DN)

200mm

 2sets

Material

 Motor

Fully enclosed anti- water type

 TEFC 

 Fan

Aluminum alloy

 

 Panelair stack

F.R.P&ABS&G.I.

 

 Water basin, suction tank

 Sprinkler system

 In fill

P.V.C

Fire-resistance type

 Motor support, framework

Hot-dip galvanized steel 

Comply with BS EN

ISO14611999 standard


2) Outline dimension of cross flow square type cooling tower NST-600, 2 cells unit

NEWIN cross flow NST-600 outline drawing

 

3) Foundation of cross flow square type cooling tower NST-600, 2 cells unit

NEWIN cross flow cooling tower NST-600 foundation drawing


 ※ We reserve the right to modify the above information without further notice.

The main parts of cooling tower consists of motor, cooling fan, infill, water distributing system, water basin, frame work, F.R.P casing, etc. We use great quality of the cooling tower parts to make sure the great performance and long lifespan of the Newin cooling towers. If customers have other special requirements for the cooling tower, we will try our best to satisfy their needs.

 

 NST motor  cooling tower fan  cross flow fills  water distributing basin
 cross flow FRP casing  HDGS steel structure  pulley reducer  floate ball valve

 

Parts  Material  Remark

Water Basin

 F.R.P Water-resistance resin and high quality fiberglass mat

 Casing

 F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type(TEFC), other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard

 Fan

 A.B.S Aluminum alloy material multi-blades low fan

 Driven system

  Hot dip galvanized steel  Belts and pulley or Gear reducer

 Infill

 P.V.C  film Hanging up type film fill with integrated drift eliminator, UPC, PP material as optional

 Flame work  

 Hot dip galvanized steel   Stainless steel 304, 316 for optional

 Water distributing system

 F.R.P.  Top water distributing water basing

 Eliminator

 P.V.C  PVC blade type eliminators e

 Bolts & Nuts 

 Electroplated   Stainless steel 304, 316 for optional






















Cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc.  Those industries  could be divided into 4 categories as follows:
♦  Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦  Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦  other industries...

 

Below is some cross flow square type cooling towers' project in different industries.

 cross flow cooling tower  newin cross flow cooling tower 
 cross flow FRP cooling tower  newin cooling tower
 yellow color square cooling tower  cross flow project
 newin cooling tower  newin cooling tower

Drawing and parameters:


Technical specification of cooling tower NST-600  2cell unit

Outline dimension drawing of cooling tower NST-600  2cell unit

Foundation size and construction drawing of cooling tower NST-600  2cell 


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • 100m³/h square type counter flow cooling tower Counter Flow Square Cooling Tower NSH-100

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • Counter Flow Box Cooling Tower NSH-225 Counter Flow Box Cooling Tower NSH-225

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • counter flow closed circuit cooling tower LKM-50 Counter flow closed circuit cooling tower LKM-50

    LKM series closed circuit cooling tower is a kind of high efficient heat exchange equipment which comes into being on the basis of absorbing the most advanced foreign heat-exchange technology.  The Air intake style is inlet from the bottom of the tower, which is alternating direction interactive with the fall down spray water and from to saturated vapor in the process. The heat is exhausted out of tower by the fan and the water is collected to bottom tank and circulate continuously by the special evaporator. There is no heat sinking fillings inside of the tower, so more space is saved to increase coil area. This apply especially to suit for smaller fluid cooling fluid in low temperature or small temperature difference.   Technical parameters of LKM series closed circuit cooling tower          Item  Water Flow (m3/h) Fan Spray Pump Inlet/Outlet  Pipe Dia.  (mm) Weight (kg) Dimension          Model Air Volume   (m3/h) Power  (KW) Flow  (m³/h) Power  (KW) Net Weight Run. Weight L×W×H      (mm) LKM-5 5 10500 0.55 14 0.75 50 T:350 600 1150x900x1920 LKM-8 8 13050 0.75 14 0.75 65 T:400 700 1150x1150x1920 LKM-10 10 26100 0.75*2 30 1.1 65 T:520 1000 2000x1150x2200 LKM-15 15 26100 0.75*2 30 1.1 65 T:570 1100 2000x1150x2200 LKM-20 20 36600 1.1*2 40 1.5 80 T:650 1600 2500x1150x2200 LKM-25 25 36600 1.1*2 40 1.5 80 T:750 1700 2500x1150x2350 LKM-35 35 40600 1.5*2 40 1.5 80 T:850 1800 2500x1400x2650 LKM-40 40 40600 1.5*2 60 1.5 100 T:1050 2000 2500x1400x2650 40600 1.5*2 60 1.5 100 G:2150 3000 3000x1400x2650 LKM-50 50 46900 2.2*2 60 1.5 100 T:1250 2300 2500x1400x2650 46900 2.2*2 60 1.5 100 G:2450 3500 3000x1400x2650 LKM-60 60 53000 2.6*2 60 1.5 100 T:1350 2400 2500x1400x2650 53000 2.6*2 60 1.5 100 G:2650 3700 3000x1400x2650 LKM-70 70 63800 3.5*2 65 2.2 100 T:1650 3000 3000x1400x2850 63800 3.5*2 65 2.2 100 G:2950 4300 3518x1400x3310 LKM-80 80 90000 4*2 65 2.2 125 T:1850 3300 3000x1400x2850 90000 4*2 65 2.2 125 G:3560 5000 3518x2180x3310 LKM-100 100 90000 4*2 110 3 125 T:2050 3800 3000x2180x2850 90000 4*2 110 3 125 G:4150 5900 3518x2180x3310 LKM-125 125 110000 5.5*2 110 3 100*2 T:2450 4300 3518x2180x3250 110000 5.5*2 110 4 100*2 G:5150 7000 4010x2180x3910 LKM-150 150 150000 7.5*2 110 3 100*2 T:3150 4300 3518x2180x2850 150000 7.5*2 140 4 100*2 G:6500 8100 4010x2980x3910 LKM-175 175 180000 7.5*2 170 5.5 100*2 T:3700 7100 4010x2980x3910 180000 7.5*2 220 7.5 100*2 G:7120 10500 5380x2980x3910 LKM-200 200 220000 7.5*2 170 5.5 125*2 T:4180 7600 4010x2980x3910 220000 7.5*2 220 7.5 125*2 G:8300 11700 5380x2980x3910 LKM-250 250 300000 11*2 170 5.5 125*2 T:5050 8900 4510x2980x3910 300000 11*2 220 7.5 125*2 G:10680 14600 5380x2180x3910 LKM-300 300 300000 7.5*4 220 3*2 100*4 T:6300 8600 7036x2180x2850 300000 7.5*4 220 3*2 100*4 G:12100 16200 8020x2980x3910 LKM-350 350 360000 7.5*4 340 5.5*2 125*4 T:7400 14200 8020x2980x3910 360000 7.5*4 440 7.5*2 125*4 G:14240 21000 107600x2980x3910 LKM-400 400 440000 7.5*4 340 5.5*2 125*4 T:8360 15200 8020x2980x3910 440000 7.5*4 440 7.5*2 125*4 G:16600 23400 107600x2980x3910 LKM-500 500 600000 11*4 340 5.5*2 125*4 T:10100 17800 8020x2980x3910 600000 11*4 440 7.5*2 125*4 G:21360 29200 107600x2980x3910  ※ We reserve the right to modify the above information without further notice.

  • cross flow closed circuit cooling tower LKH-200 cross flow closed circuit cooling tower LKH-200

    Cross flow closed circuit cooling tower LKH-200 specification   I. Design Condition Water processing capacity: 200 m3/ h △t = 5℃ ( Inlet 37℃, outlet 32℃ )          Design wet bulb temperature:28℃          Design dry bulb temperature: 31.5℃          Atmosphere: 99,400Pa D II. Selection Model    Closed circuit cross flow cooling tower     Model: LKH-200   III. Cooling tower performance data sheet(single cell)   Model LKH-200 Water flow rate 200 m3/ h Temperature in 37℃ Temperature out 32℃(2-5℃ above WBT in summer) WTB 28℃ Temperature decrease 5℃ heat exchanging capacity 1,000,000 kcal/h Power 3φ-380V/50Hz Total power 11.5 kW Drift loss 0.005% Noise level Not more than 75dB(A) According to GB9068 measurement      Axial fan Quantity 4 sets Air volume 80000m3/ h Power 1.5 Kw x 4 Speed 720r/min Air pressure 140pa   Spray pump Quantity 1 set Water volume 130 m3/ h Power 5.5 Kw Coil pressure 1.2 Mpa Water Resistance <80KPa Inlet pipe diameter DN 150 Outlet pipe diameter DN150     dimension Length 4350 mm Width 2340 mm Height 3645 mm        Weight Net weight (kg) 2650 Operation weight (kg) 6930    ※ We reserve the right to modify the above information without further notice.

  • Counter Flow Square Cooling Tower NSH-700 Counter Flow Square Cooling Tower NSH-700

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.