1)  Technical data of circular type cooling tower NRT-800

Item

Content

Parameter

Basic data

 

 Type

Counter-flow round type

 Model

NRT-800

 Water flow

626.4  m3/h

 Inlet/outlet temperature

37°C32°C

 Dry/Wet bulb temperature

31.5°C 27°C

 Cooling capacity

313,200 kcal/h

 Power supply

380V3Ph50Hz

 Water quality

PH=6-8

Design data

 Air/water ratio

0.62 kg/kg

 Drift loss

≤0.02%

 Evaporating loss

≤0.833%

 Net weight

4700 kg

 Running weight

11900 kg

Fan data

 Fan type

Axial-flow 

 Air flow

344,520 m3/h

 Fan rotate speed

220 r/min

 Diameter (F)

3700 mm

 Blade quantity

 4 pcsset

 Type of drive

Vee belt

 Motor rotate speed

960 r/min

 Motor power

22 kW 

 Motor starting method

Y-△

Dimension

 Tower diameter (F)

7,600 mm

 Tower height (H)

4,720 mm

 Inlet/outlet pipe dimension (DN)

300 mm300 mm

 Full/drain pipe dimension (DN)

100 mm100 mm

 Quick feed pipe dimension (DN)

80 mm

 

2) Overall dimension of bottle type cooling tower NRT-800

 

3) Foundation of round type cooling tower NRT-800

 

  ※ We reserve the right to modify the above information without further notice.

The Main parts of cooling tower consists of motor, fan, infill, sprinkler system, F.R.P parts, etc. We use great quality of the cooling tower parts to make sure the great performance and long lifespan of the Newin cooling towers. If customers have other special requirements for the cooling tower, we will try our best to satisfy their needs.

 

       
       

 

Parts  Material  Remark

Water Basin

 F.R.P Water-resistance resin and high quality fiberglass mat

 Casing

 F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type, other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard

 Fan

 Alum alloy stainless steel for optional 

 Infill

 P.V.C  film For high temperature inlet water, UPVC and PP material for optional

 Air inlet screen  

 P.V.C   F.R.P  for optional

 Sprinkler head

 A.B.S  Aluminum alloy material for optional

 Sprinkler pipe

 P.V.C  For high temperature inlet water, hot-dip galvanized steel for optional

 Bolts & Nuts 

 Electroplated   Stainless steel 304, 316 for optional






















Cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc.  Those industries  could be divided into 4 categories as follows:
♦  Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦  Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦  other industries...

 

Below is some round type cooling towers' project in different industries.

   
   
   
   

Drawing and parameters:


Technical specification of cooling tower NRT-800

Outline dimension drawing of cooling tower NRT-800

Foundation size and construction drawing of cooling tower NRT-800


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • 300m³/h cross flow cooling tower Fiberglass Cross Flow Cooling Tower NST-300

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • 100m³/h square type counter flow cooling tower Counter Flow Square Cooling Tower NSH-100

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • 500m³/h cross flow cooling tower cross flow cooling tower NST-500

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • Counter Flow Square Cooling Tower NSH-80 Counter Flow Square Cooling Tower NSH-80

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • RTS Counter Flow Turbine Drive Cooling Tower RTS Counter Flow Turbine Drive Cooling Tower

    Components Instruction Turbine The reaction turbine drives fan directly, no other reducer equipment. Fan air volume is changed by water flow, realizes fan, water, power integrated control Infill  Brand new PVC infill is vacuum formed of 0.3 thickness or more thicker PVC film with excellent chemical and high distortion resistance, big coefficient of heat transfer, small wind resistance, high ventilation performance.  We have different materials to suit different water temperature. What's more, the PVC filler's compact package design is convenient to take out for cleaning, and the special designed configuration of the filling incorporates the function of drift eliminator, louver and wet deck surface. Steel Structure  Hop-dip galvanized steel framework to keep the cooling tower great performance and long lifespan, good anti-corrosion, guarantee the use of more than 15 years. Stainless steel hardware parts are also available for options if somewhere special condition needed. Distribution System Hot water distribution system is used F.R.P parts, non-corrosive and long life, and are specially designed for uniform distributing and ease of inspection. A distribution cover is attached on top to prevent    water from splashing out and other dirt to come into the water.      Inspection Door Inspection doors are used to provide a convenient access to the interior for inspection, maintenance, adjustment of the internal parts, like float valve, cleaning up the lift-out strainer and flushing of the water basin.             Technical Data of RTS Series Cross Flow Turbine Cooling Tower Model Water  Flow  (m3/h)  Fan Weight (kg) Overall Dimension  (mm) Water  Pressure    (Kpa) Net  weight Run.  Weight L W H  RTS-100-1 100 1500 765 1970 1800 3160 3700 160 RTS-125-1 125 1800 910 2570 2000 3360 3700 160 RTS-150-1 150 1800 970 2800 2400 3360 3700 165 RTS-175-1 175 2100 1150 3230  2600 3960 3700 165 RTS-200-1 200 2100 1280 3580 2900 3960 3700 180 RTS-225-1 225 2400 1460 4050 2900 4260 3700 180 RTS-250-1 250 2400 1510 4310 3200 4260 3700 180 RTS-300-2 300 1800 1910 5600 4800 3360 3700 170 RTS-350-2 350 2100 2270 6430 5200 3960 3700 170 RTS-400-2 400 2100 2530 7010 5800 3960 3700 185 RTS-450-2 450 2400 2880 7960 5800 4260 3700 185  RTS-500-2 500  2400 2990  8580  6400   4260  3700  185   RTS-525-3  525 2100  3390  9630  7800   3960  3700  190   RTS-600-3  600 2100   3780 10680  8700   3960  3700  190   RTS-700-4  700 2100  4510  12830  10400   3960   3700 190   RTS-800-4  800 2100  5030  13990   11600  3960  3700  190   RTS-900-4  900 2400 5730   15890  11600  4260 3700  190   RTS-1000-5  1000 2100 6250  17630  14500   3960 3700  190    Remark:   1. Working condition: dry bulb temp.=31.5℃, wet bulb temp.=28℃, inlet water=37℃, outlet water=32℃, atmospheric pressure=99.4Kpa.   2. When installing pipeline of the cooling towers, Y-strainers, valves and pressure gauges are needed at the water inlet pipe.   3. Keep foundation surface level, error limit ±5mm.   4. Special design for other model are acceptable by technical department.  

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.