Products
Home | F.R.P. Cooling Tower | NRT Round Cooling Tower | NRT-200 | Counter Flow Round Type Cooling Tower NRT-200
Counter Flow Round Type Cooling Tower NRT-200
Product Origin Guangdong
Brand NEWIN
Item NO. NRT-200
Shipping Port Shenzhen
Color Yellow/White/Gray/Blue
Lead Time 15 working days
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

The round type cooling tower are mainly used in gas industry, air conditioning system. Here we mainly introduce the technical data, structure and foundation of the round type cooling tower NRT-200. For different working condition, please contact us for correct solution. 

  

1)  Technical data of circular type cooling tower NRT-200

Item

Content

Parameter

Basic data

 

 Type

Counter-flow round type

 Model

NRT-200

 Water flow

156.24 m3/hr

 Inlet/outlet temperature

37°C32°C

 Dry/Wet bulb temperature

31.5°C 27°C

 Cooling capacity

78,100 kcal/h

 Power supply

380V3Ph50Hz

 Water quality

PH=6-8

Design data

 Air/water ratio

0.62 kg/kg

 Drift loss

≤0.02%

 Evaporating loss

≤0.833%

 Net weight

780 kg

 Running weight

1880 kg

Fan data

 Fan type

Axial-flow 

 Air flow

85,930 m3/h

 Fan rotate speed

590 r/min

 Diameter (F)

1750 mm

 Blade quantity

 4 pcsset

 Type of drive

Vee belt

 Motor rotate speed

590 r/min

 Motor power

4 kW 

 Motor starting method

direct

Dimension

 Tower diameter (F)

3,310 mm

 Tower height (H)

3,165 mm

 Inlet/outlet pipe dimension (DN)

150 mm150 mm

 Full/drain pipe dimension (DN)

50 mm50 mm

 Quick feed pipe dimension (DN)

25 mm


2) Overall dimension of bottle type cooling tower NRT-200

 

3) Foundation of round type cooling tower NRT-200

  

※ We reserve the right to modify the above information without further notice.

The Main parts of cooling tower consists of motor, fan, infill, sprinkler system, F.R.P parts, etc. We use great quality of the cooling tower parts to make sure the great performance and long lifespan of the Newin cooling towers. If customers have other special requirements for the cooling tower, we will try our best to satisfy their needs.

 

       
       

 

Parts  Material  Remark

Water Basin

 F.R.P Water-resistance resin and high quality fiberglass mat

 Casing

 F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type, other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard

 Fan

 Alum alloy stainless steel for optional 

 Infill

 P.V.C  film For high temperature inlet water, UPVC and PP material for optional

 Air inlet screen  

 P.V.C   F.R.P  for optional

 Sprinkler head

 A.B.S  Aluminum alloy material for optional

 Sprinkler pipe

 P.V.C  For high temperature inlet water, hot-dip galvanized steel for optional

 Bolts & Nuts 

 Electroplated   Stainless steel 304, 316 for optional






















Cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc.  Those industries  could be divided into 4 categories as follows:
♦  Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦  Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦  other industries...

 

Below is some round type cooling towers' project in different industries.

   
   
   
   

Drawing and parameters:


Technical specification of cooling tower NRT-200 

Outline dimension drawing of cooling tower NRT-200

Foundation size and construction drawing of cooling tower NRT-200


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.


Recently Viewed Products
  • Square Type Cooling Tower NSH-250 Square Type Cooling Tower NSH-250

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • 800m³/h cross flow cooling tower cross flow cooling tower NST-800

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • Counter Flow Square Cooling Tower NSH-800 Counter Flow Square Cooling Tower NSH-800

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • cross flow closed circuit cooling tower LKH-200 cross flow closed circuit cooling tower LKH-200

    Cross flow closed circuit cooling tower LKH-200 specification   I. Design Condition Water processing capacity: 200 m3/ h △t = 5℃ ( Inlet 37℃, outlet 32℃ )          Design wet bulb temperature:28℃          Design dry bulb temperature: 31.5℃          Atmosphere: 99,400Pa D II. Selection Model    Closed circuit cross flow cooling tower     Model: LKH-200   III. Cooling tower performance data sheet(single cell)   Model LKH-200 Water flow rate 200 m3/ h Temperature in 37℃ Temperature out 32℃(2-5℃ above WBT in summer) WTB 28℃ Temperature decrease 5℃ heat exchanging capacity 1,000,000 kcal/h Power 3φ-380V/50Hz Total power 11.5 kW Drift loss 0.005% Noise level Not more than 75dB(A) According to GB9068 measurement      Axial fan Quantity 4 sets Air volume 80000m3/ h Power 1.5 Kw x 4 Speed 720r/min Air pressure 140pa   Spray pump Quantity 1 set Water volume 130 m3/ h Power 5.5 Kw Coil pressure 1.2 Mpa Water Resistance <80KPa Inlet pipe diameter DN 150 Outlet pipe diameter DN150     dimension Length 4350 mm Width 2340 mm Height 3645 mm        Weight Net weight (kg) 2650 Operation weight (kg) 6930    ※ We reserve the right to modify the above information without further notice.

  • cross flow closed circuit cooling tower LKH-30 cross flow closed circuit cooling tower LKH-30

    Cross flow closed circuit cooling tower LKH-30 specification   I. Design Condition Water processing capacity: 30 m3/ h △t = 5℃ ( Inlet 37℃, outlet 32℃ )          Design wet bulb temperature:28℃          Design dry bulb temperature: 31.5℃          Atmosphere: 99,400Pa D II. Selection Model    Closed circuit cross flow cooling tower     Model: LKH-30   III. Cooling tower performance data sheet(single cell)   Model LKH-30 Water flow rate 30m3/ h Temperature in 37℃ Temperature out 32℃(2-5℃ above WBT in summer) WTB 28℃ Temperature decrease 5℃ heat exchanging capacity 150,000 kcal/h Power 3φ-400V/50Hz Total power 3.7kW Drift loss 0.005% Noise level Not more than 75dB(A)  According to GB9068 measurement      Axial fan Quantity 2 sets Air volume 32000m3/ h Power 1.1Kwx2 Speed 720r/min Air pressure 140pa   Spray pump Quantity 1set Water volume 32.5 m3/ h Power 1.5Kw Coil pressure 1.2Mpa Water Resistance <80KPa Inlet pipe diameter DN80 Outlet pipe diameter DN80     dimension Length 2500 mm Width 1970 mm Height 2263 mm        Weight Net weight (kg) 850 Operation weight (kg) 3100    ※ We reserve the right to modify the above information without further notice.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.