Products
Home | Closed Circuit Cooling Tower | LKM Counter Flow | LKM-200 | Counter flow closed circuit cooling tower LKM-200
Counter flow closed circuit cooling tower LKM-200
Brand NEWIN
Item NO. LKM-200
Shipping Port Shenzhen
Color steel white
Lead Time 4-6 weeks
Payment TT,L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

LKM series closed circuit cooling tower is a kind of high efficient heat exchange equipment which comes into being on the basis of absorbing the most advanced foreign heat-exchange technology.

 The Air intake style is inlet from the bottom of the tower, which is alternating direction interactive with the fall down spray water and from to saturated vapor in the process. The heat is exhausted out of tower by the fan and the water is collected to bottom tank and circulate continuously by the special evaporator. There is no heat sinking fillings inside of the tower, so more space is saved to increase coil area. This apply especially to suit for smaller fluid cooling fluid in low temperature or small temperature difference.  


Technical parameters of LKM series closed circuit cooling tower


         Item 

Water Flow

(m3/h)

Fan

Spray Pump

Inlet/Outlet 

Pipe Dia.

 (mm)

Weight (kg)

Dimension        

 Model

Air Volume 

 (m3/h)

Power

 (KW)

Flow 

(m³/h)

Power

 (KW)

Net Weight

Run. Weight

L×W×H  

   (mm)

LKM-5

5

10500

0.55

14

0.75

50

T:350

600

1150x900x1920

LKM-8

8

13050

0.75

14

0.75

65

T:400

700

1150x1150x1920

LKM-10

10

26100

0.75*2

30

1.1

65

T:520

1000

2000x1150x2200

LKM-15

15

26100

0.75*2

30

1.1

65

T:570

1100

2000x1150x2200

LKM-20

20

36600

1.1*2

40

1.5

80

T:650

1600

2500x1150x2200

LKM-25

25

36600

1.1*2

40

1.5

80

T:750

1700

2500x1150x2350

LKM-35

35

40600

1.5*2

40

1.5

80

T:850

1800

2500x1400x2650

LKM-40

40

40600

1.5*2

60

1.5

100

T:1050

2000

2500x1400x2650

40600

1.5*2

60

1.5

100

G:2150

3000

3000x1400x2650

LKM-50

50

46900

2.2*2

60

1.5

100

T:1250

2300

2500x1400x2650

46900

2.2*2

60

1.5

100

G:2450

3500

3000x1400x2650

LKM-60

60

53000

2.6*2

60

1.5

100

T:1350

2400

2500x1400x2650

53000

2.6*2

60

1.5

100

G:2650

3700

3000x1400x2650

LKM-70

70

63800

3.5*2

65

2.2

100

T:1650

3000

3000x1400x2850

63800

3.5*2

65

2.2

100

G:2950

4300

3518x1400x3310

LKM-80

80

90000

4*2

65

2.2

125

T:1850

3300

3000x1400x2850

90000

4*2

65

2.2

125

G:3560

5000

3518x2180x3310

LKM-100

100

90000

4*2

110

3

125

T:2050

3800

3000x2180x2850

90000

4*2

110

3

125

G:4150

5900

3518x2180x3310

LKM-125

125

110000

5.5*2

110

3

100*2

T:2450

4300

3518x2180x3250

110000

5.5*2

110

4

100*2

G:5150

7000

4010x2180x3910

LKM-150

150

150000

7.5*2

110

3

100*2

T:3150

4300

3518x2180x2850

150000

7.5*2

140

4

100*2

G:6500

8100

4010x2980x3910

LKM-175

175

180000

7.5*2

170

5.5

100*2

T:3700

7100

4010x2980x3910

180000

7.5*2

220

7.5

100*2

G:7120

10500

5380x2980x3910

LKM-200

200

220000

7.5*2

170

5.5

125*2

T:4180

7600

4010x2980x3910

220000

7.5*2

220

7.5

125*2

G:8300

11700

5380x2980x3910

LKM-250

250

300000

11*2

170

5.5

125*2

T:5050

8900

4510x2980x3910

300000

11*2

220

7.5

125*2

G:10680

14600

5380x2180x3910

LKM-300

300

300000

7.5*4

220

3*2

100*4

T:6300

8600

7036x2180x2850

300000

7.5*4

220

3*2

100*4

G:12100

16200

8020x2980x3910

LKM-350

350

360000

7.5*4

340

5.5*2

125*4

T:7400

14200

8020x2980x3910

360000

7.5*4

440

7.5*2

125*4

G:14240

21000

107600x2980x3910

LKM-400

400

440000

7.5*4

340

5.5*2

125*4

T:8360

15200

8020x2980x3910

440000

7.5*4

440

7.5*2

125*4

G:16600

23400

107600x2980x3910

LKM-500

500

600000

11*4

340

5.5*2

125*4

T:10100

17800

8020x2980x3910

600000

11*4

440

7.5*2

125*4

G:21360

29200

107600x2980x3910


 ※ We reserve the right to modify the above information without further notice.

▲ Aluminium Zinc Plate

  Shell plate uses imported aluminium zinc plate, which is one of the strongest corrosion resistance plate, service life is 3-6 times of ordinary galvanized sheet, with strong termal resistance, high heat resistance, beautiful appearance, ect.  


▲ Spray Pump

Used great mechanical seal to prevent from the leakage,  made by dedicated outdoor motor, and special configuration imported bearings, to ensure that the fan, water pump has long term reliable operation, low power, large flow, low noise, excellent performance, etc. The pump body is precision casting, strong and long service life. 


▲ Drift Eliminator

It is made of PVC material installed inside the machine in groups. Dehydrating units have three turning structure to stop the

watermixed in the air flow. It can reduce the maximum rate of escaping water to the 0.1‰ of the whole recycled 

water. 


▲Air Inlet Louver

They are made of PVC material, and installed in the machine's outside surface that can be easily installed, so the inlet and outlet shaped pipes can be maintained and repaired.Spatial grids have a double structure to guide air turn and flow, so they can stop 

water spray outside and protect water pipes from being shined directly by the sun.   


▲ Cooling coil

    Cooling coils as the core parts of closed cooling tower, are made up of great quality copper coil or steel coil.  Coil inside is through cooling medium, outside is cooled by water spray to meet the cooling requirement. 
    Steel coils (G type) are used by high quality Ф25 mm seamless fluid tube, and processed by H.D.G.(hot dip galvanized) to enhance the coil pipe anti-corrosion ability, extend service life.

   Copper coils (T type) are used by T2 deoxidized acid copper tube, silver electrode is used to connect between the copper pipe and elbow welding, low solder joint and good quality, design pressure is 1.2MPa.


▲ Axial Flow Fan  

    Uses cooling tower special aluminum alloy axial flow fan,forward type blade structure design, small wind resistance, big air volume, low noise, good performance, high efficiency. Streamline high strength fan stack gurantees airflow uniform through the fan inlet and outlet area, maximum reduce the energy comsuption. Fan motor's protection class: IP55, Insulation class: F class. 
 

Components list


No.

Parts name

Unit

Parameters

Origin

Remarks

1

Cooling coil

set

Copper tube

φ19mm,

δ=0.5mm

Shanghai

 

 

2

Tower shell

set

δ= 2mm

Shenzhen

High strength galvanized steel plate, 

with great anti corrosive and heat 

insulation protection.

3

Collection basin

set

δ= 2mm

Shenzhen

Same as above

4

Dehydrator

set

PVC

Shenzhen

Drift loss rate<0.5%

5

Pre-cooling fins

set

PVC

Shenzhen

 

6

Fan impeller

unit

Alum. Alloy

Shenzhen

High strength alum. alloy

7

Fan motor

unit

Linko

Shenzhen

Protection class: IP54

Insulation class: F            

Vbelt reduction type,        

design life span: 30000 hrs

8

Motor bearing

set

NTN

Japan

Maintenance free, oil free

9

Fan stack

pc

Galvanized steel

Shenzhen

With protection shield

10

Spray pump

set

Vertical-Inline

Shenzhen

Big flow, low lift, water proof

11

Pump motor

unit

Enclosed type

Shenzhen

Based on standard JIS-C4210, 

Protection class: IP54

Insulation class: B

12

 Bearing

set

NTN

Japan

Maintenance free, oil free

13

Spray pipe

set

PVC 

Taiwan

Formosa product

14

Spray head

set

ABS, spiral nozzle 

Shenzhen

Well-distribute

15

Spray water level control

pc

S.U.S Float valve

Shanghai

Control spray water level 

automatically

16

Drain outlet

pc

S.U.S Float valve

Shanghai

 

17

Inlet/outlet 

pc

Steel flange

Shenzhen

 

18

Air-inlet grille

pc

PVC or hot -dip aluminum-zinc plate

Shenzhen

 

Application Industries:


  · Closed circuit cooling tower used in high frequency power source capacitance

 

·Closed circuit cooling tower used in Furnace

 

· Closed circuit cooling tower used in Quenching water/oil tank


 

 · Closed circuit cooling tower used in Hydraulic pressure station



·Closed circuit cooling tower used in Pressing machine


 

 · Closed circuit cooling tower used in Air compressor



· Closed circuit cooling tower used in Central air-conditioning system


 

· Closed circuit cooling tower used in Power generato


 

Drawing and parameters:


Technical specification of cooling tower LKM-200  1cell unit

Outline dimension drawing of cooling tower LKM-200  1cell unit


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • 500m³/h cross flow cooling tower cross flow cooling tower NST-500

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • cross/mixed flow closed circuit cooling tower LKH-175 cross/mixed flow closed circuit cooling tower LKH-175

    1.Water processing capacity: 175m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • counter flow closed circuit cooling tower LKM-50 Counter flow closed circuit cooling tower LKM-50

    LKM series closed circuit cooling tower is a kind of high efficient heat exchange equipment which comes into being on the basis of absorbing the most advanced foreign heat-exchange technology.  The Air intake style is inlet from the bottom of the tower, which is alternating direction interactive with the fall down spray water and from to saturated vapor in the process. The heat is exhausted out of tower by the fan and the water is collected to bottom tank and circulate continuously by the special evaporator. There is no heat sinking fillings inside of the tower, so more space is saved to increase coil area. This apply especially to suit for smaller fluid cooling fluid in low temperature or small temperature difference.   Technical parameters of LKM series closed circuit cooling tower          Item  Water Flow (m3/h) Fan Spray Pump Inlet/Outlet  Pipe Dia.  (mm) Weight (kg) Dimension          Model Air Volume   (m3/h) Power  (KW) Flow  (m³/h) Power  (KW) Net Weight Run. Weight L×W×H      (mm) LKM-5 5 10500 0.55 14 0.75 50 T:350 600 1150x900x1920 LKM-8 8 13050 0.75 14 0.75 65 T:400 700 1150x1150x1920 LKM-10 10 26100 0.75*2 30 1.1 65 T:520 1000 2000x1150x2200 LKM-15 15 26100 0.75*2 30 1.1 65 T:570 1100 2000x1150x2200 LKM-20 20 36600 1.1*2 40 1.5 80 T:650 1600 2500x1150x2200 LKM-25 25 36600 1.1*2 40 1.5 80 T:750 1700 2500x1150x2350 LKM-35 35 40600 1.5*2 40 1.5 80 T:850 1800 2500x1400x2650 LKM-40 40 40600 1.5*2 60 1.5 100 T:1050 2000 2500x1400x2650 40600 1.5*2 60 1.5 100 G:2150 3000 3000x1400x2650 LKM-50 50 46900 2.2*2 60 1.5 100 T:1250 2300 2500x1400x2650 46900 2.2*2 60 1.5 100 G:2450 3500 3000x1400x2650 LKM-60 60 53000 2.6*2 60 1.5 100 T:1350 2400 2500x1400x2650 53000 2.6*2 60 1.5 100 G:2650 3700 3000x1400x2650 LKM-70 70 63800 3.5*2 65 2.2 100 T:1650 3000 3000x1400x2850 63800 3.5*2 65 2.2 100 G:2950 4300 3518x1400x3310 LKM-80 80 90000 4*2 65 2.2 125 T:1850 3300 3000x1400x2850 90000 4*2 65 2.2 125 G:3560 5000 3518x2180x3310 LKM-100 100 90000 4*2 110 3 125 T:2050 3800 3000x2180x2850 90000 4*2 110 3 125 G:4150 5900 3518x2180x3310 LKM-125 125 110000 5.5*2 110 3 100*2 T:2450 4300 3518x2180x3250 110000 5.5*2 110 4 100*2 G:5150 7000 4010x2180x3910 LKM-150 150 150000 7.5*2 110 3 100*2 T:3150 4300 3518x2180x2850 150000 7.5*2 140 4 100*2 G:6500 8100 4010x2980x3910 LKM-175 175 180000 7.5*2 170 5.5 100*2 T:3700 7100 4010x2980x3910 180000 7.5*2 220 7.5 100*2 G:7120 10500 5380x2980x3910 LKM-200 200 220000 7.5*2 170 5.5 125*2 T:4180 7600 4010x2980x3910 220000 7.5*2 220 7.5 125*2 G:8300 11700 5380x2980x3910 LKM-250 250 300000 11*2 170 5.5 125*2 T:5050 8900 4510x2980x3910 300000 11*2 220 7.5 125*2 G:10680 14600 5380x2180x3910 LKM-300 300 300000 7.5*4 220 3*2 100*4 T:6300 8600 7036x2180x2850 300000 7.5*4 220 3*2 100*4 G:12100 16200 8020x2980x3910 LKM-350 350 360000 7.5*4 340 5.5*2 125*4 T:7400 14200 8020x2980x3910 360000 7.5*4 440 7.5*2 125*4 G:14240 21000 107600x2980x3910 LKM-400 400 440000 7.5*4 340 5.5*2 125*4 T:8360 15200 8020x2980x3910 440000 7.5*4 440 7.5*2 125*4 G:16600 23400 107600x2980x3910 LKM-500 500 600000 11*4 340 5.5*2 125*4 T:10100 17800 8020x2980x3910 600000 11*4 440 7.5*2 125*4 G:21360 29200 107600x2980x3910  ※ We reserve the right to modify the above information without further notice.

  • 200m³/h counter flow cooling tower Counter Flow Box Cooling Tower NSH-200

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • 600RT counter flow cooling tower Counter Flow Round Type Cooling Tower NRT-600

    NRT series cooling towers' performance was strictly examined by "Quality Supervision and Inspection Center of National Glass work" in 2006, the result showed NRT series cooling towers completely comply with all national standards.   Design Features NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.   Casing and Water Basin Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.   Fan Blades Aluminum alloy axial flow fan with adjustable pitch blades are applied and being balanced so that it can operation stably and quietly. Blades of fan can be adjusted according to the requirement of air volume.To assure that the maximum effective of exhausting air.     Fan Drive Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.   Water Distribution   The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance.       Infill    Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degreeC water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.    

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.