Products
Home | F.R.P. Cooling Tower | NSH Counter Flow Tower | NSH-150 | Box Type Cooling Tower NSH-150
Box Type Cooling Tower NSH-150
Product Origin Guangdong
Brand NEWIN
Shipping Port Shenzhen
Color Yellow/White/Gray/Blue
Lead Time 15 working days
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

NSH Counter Flow Cooling Tower Features


* Cooling capacity from 100 tons to 1500 tons per cell, for big cooling capacity, multi-cells are supplied.
* Great quality firm fiberglass reinforced plastic (F.R.P) parts resist corrosion.
* PVC drift eliminate to avoid the big water loss from the cooling tower.
* PVC filling (or PP infill for high temp.) is designed for maximum air/water contact for efficient heat transfer.
* Self-rotating sprinkler system with non-clog openings for long service life.
* Well adjusted Aluminum alloy or stainless steel (for options) drive fan to make sure its long service life.

* Totally enclosed fan motor is designed for outdoor operation - stands up to severe service duty.

* Galvanized motor mounts and discharge grille resist corrosion, never need painting. 
* Convenient inspection door make it easy to reach the inside for maintenance or replacing the parts .

* Access ladders make it easy to reach the fan and motors, and check the parts service condition.

 


1)  Technical Data of Square Type Counter Flow Cooling Tower NSH-150

Item

Content

Parameter

Note

Basic data

 

 Type

Counter flow square type

Low noise type

 Model

NSH-150-SA

 

 Water flow

150 m3/h

 

 Inlet / outlet temperature

37C/ 32C

ΔT=5C

 Dry / Wet bulb temperature

31.5C/ 28C

 

 Cooling capacity

600,000 kcal/h

 

 Noise value

59.5 dB(A)

5.4 M distance

 Power supply

380V3Ph50Hz

  

 Water quality

PH=6-8

 

Design data

 Air/water ratio

0.68 kg/kg

 

 Tower head

4.45 m

 

 Blanching loss

0.005%

 

 Evaporating loss

0.833 %

 

 Net weight

1420 kg

 

 Running weight

2990 kg

 

Fan data

 Fan type

Axial-flow 

 

 Air flow

105,000m3/h 

 

 Static pressure

74 Pa

 

 Fan rotate speed

303 r/min

 

 DiameterF

 2,1o0 mm

 

 Blade quantity

4 pcsset

 

 Motor power

4 kw

 

 Type of drive

direct

 

 Motor starting method

direct

 

Dimension

 L × W × H

2,250×2,250×4,070 mm

 

 Inlet pipe dimension (DN)

150 mm

Outlet pipe dimension (DN)

150mm

 Full/drain pipe dimension (DN)

80 mm80 mm

 Automatic/manual feed water 

pipe dimension (DN)

25 mm25 mm

Material

 Motor

TEFC

totally fully enclosed

 Fan

Alloy aluminum

 

 Casing, air inlet louver

F.R.P

 

 Fan stack

 Water basin, suction tank

 infill

 P.V.C

Fire-resistance type

 Sprinkler system

 PVC/Galvanized steel & A.B.S

 

 

 Framework,  Motor support

Hot Dip Galvanized Steel

Britain BS EN ISO

1461:1999 

Standard





















































※ For different working condition or special request, please query us for correct solution.

 

2) Overall dimension of counter flow square cooling water tower NSH-150

 

3) Foundation of counter flow square type water cooling tower NSH-150

  

※ We reserve the right to modify the above information without further notice.

 

Counter Flow Cooling Tower Main parts details


The Main parts of cooling tower consists of Motor, Fan, Infill, Sprinkler system, Drift Eliminator, F.R.P parts, etc. Newin Cooling towers are used great quality of the cooling tower parts to make sure the great performance and long lifespan. If customers have  special requirements for the cooling tower, we will try our best to satisfy your needs.

 

 

     Cooling tower Motor

 

 Cooling tower fan system

 

       Cooling tower infill

 

 Cooling tower Eliminator

       

 

    Tower inside structure

 

  Cooling tower structure

 

    Tower air inlet louver

 

     Cooling tower nozzle

 

 

Parts  Material  Remark

Water Basin

 F.R.P Water-resistance resin and high quality fiberglass mat

 Casing

 F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type, other brand motors for option
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard

 Fan

 Alum alloy F.R.P for optional 

 Infill

 P.V.C  film For high temperature inlet water, UPVC and PP material for option
 Drift Eliminator  P.V.C For high temperature inlet water, UPVC  material for option

 Air inlet louver

 F.R.P  Fiberglass Reinforced Plastic

 Sprinkler nozzle

 A.B.S  For high temperature inlet water, PP material for option

 Sprinkler pipe

 P.V.C  For high temperature inlet water, hot-dip galvanized steel for optional

 Bolts & Nuts 

 Electroplated   Stainless steel 304, 316 for optional
 Framework  Hot dip galvanized  steel   In accordance with BS EN ISO1461:1999 standard

























※ For different working condition or special request, please query us for correct solution.


Cooling Tower Application


The counter flow cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc.  Those industries  could be divided into 4 categories as follows:

♦  Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦  Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦  other industries...

 

Below is some square type counter flow cooling towers' projects in different industries.

 

  Cooling Tower NSH-250-SA x 3 sets

 

   Cooling Tower NSH-750-TA, 3 cells

   

 

  Cooling Tower NSH-400-MA, 4 cells

 

                       Cooling Tower NSH-200-SA

   

 

                     Cooling Tower NSH-300-SA x 2 sets

 

                 Cooling Tower NSH-1000-DA, 2 cells

   

 

                Cooling Tower NSH-800-DL, 2 cells

 

                    Cooling Tower NSH-900-DL, 2 cells



Drawing and parameters:


Technical specification of cooling tower NSH-150  1cell unit

Outline dimension drawing of cooling tower NSH-150  1cell unit

Foundation size and construction drawing of cooling tower NSH-150  1cell 


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • counter flow cooling tower Counter Flow Square Cooling Tower NSH-500

    NSH Series Counter flow Fiberglass Reinforced Plastic Square Type cooling towers uses counter flow air heat exchange technology, the cooling tower packing / cooling tower infill is made of high quality modified polyvinyl chloride (PVC) wave plate, to spread  the drench water area, and adopts fixed water sprinkling system, selection of ABS low pressure water spray nozzle, uniform water distribution, long service life, and with low water head, to save water distribution power system.

  • 175m³/h cross flow cooling tower cross flow cooling tower NST-175

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • cross/mixed flow closed circuit cooling tower LKH-250 cross/mixed flow closed circuit cooling tower LKH-250

    1.Water processing capacity: 250m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • 150m³/h cross flow cooling tower cross flow cooling tower NST-150

    Features of NEWIN square type cross flow cooling tower Space saving, light-duty structures Using specially designed infill which ensure high efficient heat transferring, heat transfer area increased significantly, smaller installing area, due to the optimization design of steel structure, operating weight greatly reduced accordingly. Energy saving Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements. Low noise Special designed low noise FRP/aluminum alloy material wing type axial flow fan and motor, so as to reduce the running noise of cooling tower. Lower running noise for super low noise models, fully meet the environmental friendly requirements. If double speed motor running at low speed in the night, the noise can go down by 2 to 3 db (A). The user who needs double speed motor please comment when placing the order. Good corrosion resistance Tower casing, tank and panel are make up of high corrosion resistance performance FRP material, adding light stabilizer to the gel coating to make it good anti-aging performance and not fade. Galvanized steel structure to improve the corrosion resistance performance of the cooling tower, no need additional anti-corrosion within normal service life. Convenient combination Combinations can be used to meet the requirements of different working conditions, users can decide combine or not according to the field situation. What’s more, adjust the cooling tower combination appearance according to surrounding buildings’ structure characteristics. If limited space in end user, our company can also design for the special cooling tower to meet users’ requirements for the performance of thermal and noise. Easy maintenance This series of cooling towers are modular design, air chamber of adjacent cooling towers are separated from each other, maintenance, packing cleaning, pipe cleaning, water tank cleaning can be done under cooling tower normal working.

  • 800RT round type cooling tower Counter Flow Round Type Cooling Tower NRT-800

    NRT series cooling towers' performance was strictly examined by "Quality Supervision and Inspection Center of National Glass work" in 2006, the result showed NRT series cooling towers completely comply with all national standards.   Design Features NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.   Casing and Water Basin Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.   Fan Blades Aluminum alloy axial flow fan with adjustable pitch blades are applied and being balanced so that it can operation stably and quietly. Blades of fan can be adjusted according to the requirement of air volume.To assure that the maximum effective of exhausting air.     Fan Drive Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.   Water Distribution   The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance.       Infill    Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degreeC water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.    

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.