Products
Home | F.R.P. Cooling Tower | NRT Round Cooling Tower | NRT-400 | Bottle Type Cooling Tower NRT-400
Bottle Type Cooling Tower NRT-400
Product Origin Guangdong
Brand NEWIN
Item NO. NRT-400
Shipping Port Shenzhen
Color Yellow/White/Gray/Blue
Lead Time 2-3 weeks
Payment TT, L/C, West Union
Contact Now
  • Specification
  • Main parts
  • Application
  • Product Literation

The round type cooling tower are mainly used in gas industry, air conditioning system. Here we mainly introduce the technical data, structure and foundation of the round type cooling tower NRT-400. For different working condition, please contact us for correct solution. 

  

1)  Technical data of circular type cooling tower NRT-400

Item

Content

Parameter

Basic data

 

 Type

Counter-flow round type

 Model

NRT-400

 Water flow

312.1  m3/h

 Inlet/outlet temperature

37°C32°C

 Dry/Wet bulb temperature

31.5°C 27°C

 Cooling capacity

156,050 kcal/h

 Power supply

380V3Ph50Hz

 Water quality

PH=6-8

Design data

 Air/water ratio

0.62 kg/kg

 Drift loss

≤0.02%

 Evaporating loss

≤0.833%

 Net weight

2840 kg

 Running weight

5740 kg

Fan data

 Fan type

Axial-flow 

 Air flow

171,660 m3/h

 Fan rotate speed

275 r/min

 Diameter (F)

2745 mm

 Blade quantity

 4 pcsset

 Type of drive

Vee belt

 Motor rotate speed

1410 r/min

 Motor power

11 kW

 Motor starting method

Y-△

Dimension

 Tower diameter (F)

5,600 mm

 Tower height (H)

3,840 mm

 Inlet/outlet pipe dimension (DN)

200 mm200 mm

 Full/drain pipe dimension (DN)

80 mm80 mm

 Quick feed pipe dimension (DN)

40 mm

 

2) Overall dimension of bottle type cooling tower NRT-400

 

3) Foundation of round type cooling tower NRT-400

 

  ※ We reserve the right to modify the above information without further notice.

The Main parts of cooling tower consists of motor, fan, infill, sprinkler system, F.R.P parts, etc. We use great quality of the cooling tower parts to make sure the great performance and long lifespan of the Newin cooling towers. If customers have other special requirements for the cooling tower, we will try our best to satisfy their needs.

 

       
       

 

Parts  Material  Remark

Water Basin

 F.R.P Water-resistance resin and high quality fiberglass mat

 Casing

 F.R.P Water-resistance resin and high quality fiberglass mat
 Motor  Cast Iron Fully enclosed anti water type, other brand motors for optional
 Motor support  Hot dip galvanized  steel  In accordance with BS EN ISO1461:1999 standard

 Fan

 Alum alloy stainless steel for optional 

 Infill

 P.V.C  film For high temperature inlet water, UPVC and PP material for optional

 Air inlet screen  

 P.V.C   F.R.P  for optional

 Sprinkler head

 A.B.S  Aluminum alloy material for optional

 Sprinkler pipe

 P.V.C  For high temperature inlet water, hot-dip galvanized steel for optional

 Bolts & Nuts 

 Electroplated   Stainless steel 304, 316 for optional






















Cooling tower is mainly used in air conditioning cooling system, frozen industry, injection molding, tanning, foaming, electricity, steam turbine, aluminum processing, air compressors, industrial water cooling, etc.  Those industries  could be divided into 4 categories as follows:
♦  Air temperature adjust : air conditioning, refrigerator, freezer, refrigeration, air conditioning, etc.;
♦  Manufacturing and processing: the food industry, pharmaceutical industry, metal casting, plastic industry, rubber industry, textile industry, steel mills, chemical industry, petrochemical products, etc.;
♦ Cooling the running machines: mechanical operation of the generator, steam turbine, air compressor, hydraulic press, engine, etc.;
♦  other industries...

 

Below is some round type cooling towers' project in different industries.

   
   
   
   

Drawing and parameters:


Technical specification of cooling tower NRT-400

Outline dimension drawing of cooling tower NRT-400

Foundation size and construction drawing of cooling tower NRT-400


Note: 

The list technical details shall not be binding unless confirmed in writing by NEWIN. 

We reserve the rights to modify the technical details without further notice.
Recently Viewed Products
  • Counter Flow Square Cooling Tower NSH-900 Counter Flow Square Cooling Tower NSH-900

    NSH series counter flow square type cooling tower is available in capacity for single cell from 40 tons to 1000 tons, various modular combinations of cooling towers are designed to meet different requirements. This type of cooling tower is mainly used in heating, ventilation, air-conditioning, and light to medium processing applications.

  • Counter Flow Round Type Cooling Tower NRT-350 Counter Flow Round Type Cooling Tower NRT-350

    NRT series cooling towers' performance was strictly examined by "Quality Supervision and Inspection Center of National Glass work" in 2006, the result showed NRT series cooling towers completely comply with all national standards.   Design Features NRT series counter flow induced draft cooling tower is designed with bottle type structure, So that the volume of prevailing air is minimized. Every part of the cooling tower is designed and made precisely and further permits easy installation and endurance due to light weight and strong structure. The testing report of cooling capacity proves its high efficiency.   Casing and Water Basin Adopting small ventilation resistance packing and special designed FRP/aluminum alloy high efficiency fan, greatly reduced the motor power. Smaller motor power are designed for low noise model, save more power, double speed motor for optional to power saving according to customers’ special requirements.Fiberglass reinforced polyester(FRP) is applied with water-resistance resin and high quality fiberglass mat. With good moisture, high gel,high strength, spray the gel-coat on FRP parts by machine and is thermal formed. The surface is as smooth as mirror and could resist ultraviolet radiation. Also, it is colorfast and durable.   Fan Blades Aluminum alloy axial flow fan with adjustable pitch blades are applied and being balanced so that it can operation stably and quietly. Blades of fan can be adjusted according to the requirement of air volume.To assure that the maximum effective of exhausting air.     Fan Drive Small capacity cooling tower adopts direct drive low noise fan. Bigger capacity fan equipped with Belt drive speed reducer. Adjust belt tension through automatic spring to save the manual maintenance. Total enclosed structure can assure the low noise operation. This series of cooling tower have passed the GB7190.1-1997 quality certification of supper low noise. Further more the belt is durable without negative effect from water vapor and sunshine.   Water Distribution   The using of high coefficient rotating sprinkler heads made of reinforced plastic or aluminum alloy can reduce the pressure of friction loss. Besides, the water can be distributed evenly to achieve the max thermal performance.       Infill    Standard and low noise cooling tower are using high class thermal formed PVC sheet. The sheets are added with industrial plaits material and long fiberglass to slow the aging and increase the strength. Moreover the water film is thinner and longer so that the infill cabbage coefficient is higher. The infill is formed in the factory, instead of at construction site. To avoid uneven problem during installing. And it cold be easily cleaned and maintained in future. High temperature cooling tower is using P.P. Infill that could withstand up to 90 degreeC water temperature. The surface of such infill is corrugated to increase the filling pitch to make sure that infill is clog-free and overcome the problem of water quality.    

  • cross/mixed flow closed circuit cooling tower LKH-50 cross/mixed flow closed circuit cooling tower LKH-50

    1.Water processing capacity: 50m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

  • LKM-N Series Compact Unit Closed Circuit Cooling Tower LKM-N Series Compact Unit Closed Circuit Cooling Tower

      Compact unit closed circuit cooling tower is a type of cooling tower which compact with counter flow closed circuit cooling tower, buffer water tank, circulating water pump, pipes, control cabinet and filter system(options). The compact design makes cooling tower can independent working with out any other auxiliary equipment. Because of the compact design, Fully functional, easy installation, the cooling tower are widely used in different industries. Due to big size of compact unit. At present, the compact unit closed circuit cooling tower could only suite for cooling tower capacity below 60m³/h.          Technical parameters of LKM-N series closed circuit cooling tower          Item Water  Flow  (m3/hr) Fan Spray Pump Inlet/Outlet  Pipe Dia.  (mm) Weight (kg) Dimension          Model Air Volume   (m3/hr) Power  (KW) Flow  (m³/hr) Power  (KW) Net Weight Run. Weight L×W×H  (mm) LKM-N5 5 10500 0.55 14 0.75 50 T:350 600 2150x900x1920 LKM-N8 8 13050 0.75 14 0.75 65 T:400 700 2150x1150x1920 LKM-N10 10 26100 0.75*2 30 1.1 65 T:520 1000 2400x1150x2200 LKM-N15 15 26100 0.75*2 30 1.1 65 T:570 1100 2400x1150x2200 LKM-N20 20 36600 1.1*2 40 1.5 80 T:650 1600 2400x1150x2200 LKM-N25 25 36600 1.1*2 40 1.5 80 T:750 1700 3600x1150x2350 LKM-N35 35 40600 1.5*2 40 1.5 80 T:850 1800 3600x1400x2650 LKM-N40 40 40600 1.5*2 60 1.5 100 T:1050 2000 3600x1400x2650 LKM-N50 50 46900 2.2*2 60 1.5 100 T:1250 2300 3600x1400x2650 LKM-N60 60 53000 2.6*2 60 1.5 100 T:1350 2400 3600x1400x2650 Note:  1. Design condition: Wet bulb temp. 28°C, standard temperature difference is 5°C.                                                                                               2. All cooling coil connection is approximate position, we will change according to actual working condition.                                                  3. We reserve the right to modify the above information without further notice.     

  • cross/mixed flow closed circuit cooling tower LKH-80 cross/mixed flow closed circuit cooling tower LKH-80

    1.Water processing capacity: 80m3/ h 2.△t = 5℃( Inlet37℃, outlet 32℃ ) 3. Design wet bulb temperature:28℃ Warranty, and after service. 1.Warranty period:12 month. Any damage caused by supplier, should provide free technical service, and free replacement parts; 2.Engineer should be send by supplier for installing and commissioning.

Copyright © Shenzhen Newin Machinery Co., Ltd.All Rights Reserved.